4.16 Kv Switchgear - MNS-(MLS) Type Low Voltage Switchgear – Xinneng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With this motto in mind, we've come to be one of quite possibly the most technologically innovative, cost-efficient, and price-competitive manufacturers for Walk In Cooler Refrigeration System, Solar Thermal Energy, Ground Mount Solar System, We will wholeheartedly welcome all clients in the industry both at home and abroad to cooperate hand in hand, and create a bright future together.
4.16 Kv Switchgear - MNS-(MLS) Type Low Voltage Switchgear – Xinneng Detail:

Scope of Application

MNS type low-voltage switchgear (hereinafter referred to as low-voltage switchgear) is a product that our company combines with the development trend of our country’s low-voltage switchgear, improves the selection of its electrical components and cabinet structure, and re-registers it.The electrical and mechanical properties of the product fully meet the technical requirements of the original MNS product.

This low-voltage switchgear is suitable for power systems with AC 50-60HZ and rated working voltage of 660V and below, as equipment control for power generation, power transmission, distribution, power conversion and power consumption.

In addition to general land use, this low-voltage switchgear can also be used in offshore oil drilling platforms and nuclear power plants after special treatment.

This low-voltage switchgear complies with IEC439, VDE0660 Part 5, GB7251.12-2013 “Low-voltage switchgear and control equipment Part 2: Complete power switch and control equipment” standards and JB/T9661 “Low-voltage withdrawable switchgear” industry standard.

Operating Environment Conditions

1. The ambient temperature should not be higher than +40℃, and the average temperature within 24 hours should not be higher than +35℃, and the minimum ambient temperature should not be lower than -5℃.

2. The relative humidity does not exceed 50% when the highest temperature is +40℃, and higher relative humidity is allowed at lower temperatures (for example: 90% when +20℃).

3. The altitude does not exceed 2000m.

4. It is allowed to transport and store under the temperature condition of -25℃—+50℃, and allow the temperature not to exceed +70℃ within 24 hours.

5.The earthquake intensity is less than 9 degrees.

Model and Its Meaning

3

The Main Technical Parameters

1. The main technical parameters of MNS type low voltage switch cabinet are shown in Table 1

Rated working voltage (V)

380, 660

Rated insulation voltage (V)

660

Rated working current (A)

Horizontal bus

630-5000

Vertical bus

800-2000*

Rated short-time withstand current

Effective value (1S)/Peak (KA)

Horizontal bus

50-100/105-250

Vertical bus

60/130-150

Enclosure protection class

IP30, IP40, IP54**

Dimensions (width * depth * height, mm)

600*800, 1000*600,  (1000)*2200

Rated working current of vertical bus: 800A for drawout type MCC for single or double side operation, 1000A for movable type; 800-2000A for single side operation MCC with cabinet depth of 1000mm.

The protection grade IP54 is not recommended due to serious derating.

Order Instructions

When ordering, the user should provide the following data:

1. Primary circuit scheme and single-line system diagram.

2. Secondary circuit schematic diagram or wiring diagram.

3. Arrangement drawing of switch cabinet and floor plan of power distribution room.

4. Layout drawing of various electrical equipment installed in each switchgear.

5. Provide the working current and short-circuit current of the horizontal bus, and select the bus specification according to the factory standard. The factory standard bus specification is 10*30*2, 10*60*2, 10*80*2, 10*60*4, 10*80 *2*2,10*60*4*2, if the bus specification is not specified, it will be selected by the factory.

6. Provide the name of each circuit, the number of words is limited to 10 words, if not provided, the manufacturer only provides a blank sign board.

7. If you need to mark the function name of the control switch or transfer switch or button in the auxiliary circuit, you need to provide the content。

8. The test position of the drawer is realized by a position switch. If this test position is required, the contact must be connected in the system.


Product detail pictures:

4.16 Kv Switchgear - MNS-(MLS) Type Low Voltage Switchgear – Xinneng detail pictures

4.16 Kv Switchgear - MNS-(MLS) Type Low Voltage Switchgear – Xinneng detail pictures


Related Product Guide:

With our leading technology at the same time as our spirit of innovation,mutual cooperation, benefits and development, we are going to build a prosperous future alongside one another with your esteemed enterprise for 4.16 Kv Switchgear - MNS-(MLS) Type Low Voltage Switchgear – Xinneng , The product will supply to all over the world, such as: Brazil, Latvia, Sao Paulo, Our business activities and processes are engineered to make sure our customers have access to widest range of products with the shortest supply time lines. This achievement is made possible by our highly skilled and experienced team. We look for people who want to grow with us around the globe and stand out from the crowd. We now have people who embrace tomorrow, have vision, love stretching their minds and going far beyond what they thought was achievable.
  • We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Marina from Georgia - 2018.11.11 19:52
    Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Daphne from Sevilla - 2017.12.31 14:53
    Write your message here and send it to us