We pursue the administration tenet of "Quality is remarkable, Services is supreme, Status is first", and will sincerely create and share success with all customers for No Cost Solar, 16kw Solar System, Whole House Solar System Cost, We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
Sa Switchgear - MNS-(MLS) Type Low Voltage Switchgear – Xinneng Detail:

Scope of Application

MNS type low-voltage switchgear (hereinafter referred to as low-voltage switchgear) is a product that our company combines with the development trend of our country’s low-voltage switchgear, improves the selection of its electrical components and cabinet structure, and re-registers it.The electrical and mechanical properties of the product fully meet the technical requirements of the original MNS product.

This low-voltage switchgear is suitable for power systems with AC 50-60HZ and rated working voltage of 660V and below, as equipment control for power generation, power transmission, distribution, power conversion and power consumption.

In addition to general land use, this low-voltage switchgear can also be used in offshore oil drilling platforms and nuclear power plants after special treatment.

This low-voltage switchgear complies with IEC439, VDE0660 Part 5, GB7251.12-2013 “Low-voltage switchgear and control equipment Part 2: Complete power switch and control equipment” standards and JB/T9661 “Low-voltage withdrawable switchgear” industry standard.

Operating Environment Conditions

1. The ambient temperature should not be higher than +40℃, and the average temperature within 24 hours should not be higher than +35℃, and the minimum ambient temperature should not be lower than -5℃.

2. The relative humidity does not exceed 50% when the highest temperature is +40℃, and higher relative humidity is allowed at lower temperatures (for example: 90% when +20℃).

3. The altitude does not exceed 2000m.

4. It is allowed to transport and store under the temperature condition of -25℃—+50℃, and allow the temperature not to exceed +70℃ within 24 hours.

5.The earthquake intensity is less than 9 degrees.

Model and Its Meaning

3

The Main Technical Parameters

1. The main technical parameters of MNS type low voltage switch cabinet are shown in Table 1

Rated working voltage (V)

380, 660

Rated insulation voltage (V)

660

Rated working current (A)

Horizontal bus

630-5000

Vertical bus

800-2000*

Rated short-time withstand current

Effective value (1S)/Peak (KA)

Horizontal bus

50-100/105-250

Vertical bus

60/130-150

Enclosure protection class

IP30, IP40, IP54**

Dimensions (width * depth * height, mm)

600*800, 1000*600,  (1000)*2200

Rated working current of vertical bus: 800A for drawout type MCC for single or double side operation, 1000A for movable type; 800-2000A for single side operation MCC with cabinet depth of 1000mm.

The protection grade IP54 is not recommended due to serious derating.

Order Instructions

When ordering, the user should provide the following data:

1. Primary circuit scheme and single-line system diagram.

2. Secondary circuit schematic diagram or wiring diagram.

3. Arrangement drawing of switch cabinet and floor plan of power distribution room.

4. Layout drawing of various electrical equipment installed in each switchgear.

5. Provide the working current and short-circuit current of the horizontal bus, and select the bus specification according to the factory standard. The factory standard bus specification is 10*30*2, 10*60*2, 10*80*2, 10*60*4, 10*80 *2*2,10*60*4*2, if the bus specification is not specified, it will be selected by the factory.

6. Provide the name of each circuit, the number of words is limited to 10 words, if not provided, the manufacturer only provides a blank sign board.

7. If you need to mark the function name of the control switch or transfer switch or button in the auxiliary circuit, you need to provide the content。

8. The test position of the drawer is realized by a position switch. If this test position is required, the contact must be connected in the system.


Product detail pictures:

Sa Switchgear - MNS-(MLS) Type Low Voltage Switchgear – Xinneng detail pictures

Sa Switchgear - MNS-(MLS) Type Low Voltage Switchgear – Xinneng detail pictures


Related Product Guide:

Our aim would be to fulfill our shoppers by offering golden company, very good value and good quality for Sa Switchgear - MNS-(MLS) Type Low Voltage Switchgear – Xinneng , The product will supply to all over the world, such as: Panama, UK, Stuttgart, If any product meed your demand, remember to feel free to contact us. We're sure your any inquiry or requirement will get prompt attention, high-quality merchandise, preferential prices and cheap freight. Sincerely welcome friends all over the world to call or come to visit, to discuss cooperation for a better future!
  • This supplier offers high quality but low price products, it is really a nice manufacturer and business partner.
    5 Stars By Mandy from Macedonia - 2017.12.31 14:53
    Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!
    5 Stars By Lisa from South Africa - 2017.12.19 11:10
    Write your message here and send it to us