Switchgear Control Panel - MNS-(MLS) Type Low Voltage Switchgear – Xinneng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" as well as the theory of "quality the basic, have confidence in the very first and management the advanced" for Air Cooling Fan, Diy Off Grid Solar Power Systems, Pv Mounting Systems, Good quality is the key factor for the company to stand out from other competitors. Seeing is Believing, want more information? Just trial on its products!
Switchgear Control Panel - MNS-(MLS) Type Low Voltage Switchgear – Xinneng Detail:

Scope of Application

MNS type low-voltage switchgear (hereinafter referred to as low-voltage switchgear) is a product that our company combines with the development trend of our country’s low-voltage switchgear, improves the selection of its electrical components and cabinet structure, and re-registers it.The electrical and mechanical properties of the product fully meet the technical requirements of the original MNS product.

This low-voltage switchgear is suitable for power systems with AC 50-60HZ and rated working voltage of 660V and below, as equipment control for power generation, power transmission, distribution, power conversion and power consumption.

In addition to general land use, this low-voltage switchgear can also be used in offshore oil drilling platforms and nuclear power plants after special treatment.

This low-voltage switchgear complies with IEC439, VDE0660 Part 5, GB7251.12-2013 “Low-voltage switchgear and control equipment Part 2: Complete power switch and control equipment” standards and JB/T9661 “Low-voltage withdrawable switchgear” industry standard.

Operating Environment Conditions

1. The ambient temperature should not be higher than +40℃, and the average temperature within 24 hours should not be higher than +35℃, and the minimum ambient temperature should not be lower than -5℃.

2. The relative humidity does not exceed 50% when the highest temperature is +40℃, and higher relative humidity is allowed at lower temperatures (for example: 90% when +20℃).

3. The altitude does not exceed 2000m.

4. It is allowed to transport and store under the temperature condition of -25℃—+50℃, and allow the temperature not to exceed +70℃ within 24 hours.

5.The earthquake intensity is less than 9 degrees.

Model and Its Meaning

3

The Main Technical Parameters

1. The main technical parameters of MNS type low voltage switch cabinet are shown in Table 1

Rated working voltage (V)

380, 660

Rated insulation voltage (V)

660

Rated working current (A)

Horizontal bus

630-5000

Vertical bus

800-2000*

Rated short-time withstand current

Effective value (1S)/Peak (KA)

Horizontal bus

50-100/105-250

Vertical bus

60/130-150

Enclosure protection class

IP30, IP40, IP54**

Dimensions (width * depth * height, mm)

600*800, 1000*600,  (1000)*2200

Rated working current of vertical bus: 800A for drawout type MCC for single or double side operation, 1000A for movable type; 800-2000A for single side operation MCC with cabinet depth of 1000mm.

The protection grade IP54 is not recommended due to serious derating.

Order Instructions

When ordering, the user should provide the following data:

1. Primary circuit scheme and single-line system diagram.

2. Secondary circuit schematic diagram or wiring diagram.

3. Arrangement drawing of switch cabinet and floor plan of power distribution room.

4. Layout drawing of various electrical equipment installed in each switchgear.

5. Provide the working current and short-circuit current of the horizontal bus, and select the bus specification according to the factory standard. The factory standard bus specification is 10*30*2, 10*60*2, 10*80*2, 10*60*4, 10*80 *2*2,10*60*4*2, if the bus specification is not specified, it will be selected by the factory.

6. Provide the name of each circuit, the number of words is limited to 10 words, if not provided, the manufacturer only provides a blank sign board.

7. If you need to mark the function name of the control switch or transfer switch or button in the auxiliary circuit, you need to provide the content。

8. The test position of the drawer is realized by a position switch. If this test position is required, the contact must be connected in the system.


Product detail pictures:

Switchgear Control Panel - MNS-(MLS) Type Low Voltage Switchgear – Xinneng detail pictures

Switchgear Control Panel - MNS-(MLS) Type Low Voltage Switchgear – Xinneng detail pictures


Related Product Guide:

We have been committed to offering easy,time-saving and money-saving one-stop purchasing service of consumer for Switchgear Control Panel - MNS-(MLS) Type Low Voltage Switchgear – Xinneng , The product will supply to all over the world, such as: Wellington, Lyon, USA, Our company will continue to adhere to the " superior quality, reputable, the user first " principle wholeheartedly. We warmly welcome friends from all walks of life to visit and give guidance, work together and create a brilliant future!
  • The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Eric from Austria - 2017.12.19 11:10
    Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
    5 Stars By Elma from Boston - 2018.09.19 18:37
    Write your message here and send it to us